A solar charger gathers energy from your solar panels, and stores it in your batteries. Using the latest, fastest technology, BlueSolar maximises this energy-harvest, driving it intelligently to achieve full charge in the shortest possible time. BlueSolar maintains battery health, extending its life.
Product Features:
-
Ultra-Fast MPPT Technology
Maximizes energy harvest by up to 30% in low or changing light conditions compared to PWM controllers, and up to 10% more than slower MPPT units. -
Load Output Protection
Prevents battery over-discharge by disconnecting loads at a preset voltage. Load output is short-circuit proof and supports inverter control via interface cable. -
Intelligent Battery Life Algorithm
Extends battery lifespan by adjusting load disconnect levels to ensure full battery recharge at least once per week, reducing harmful partial charge cycles. -
Programmable Charging
Fully configurable charge algorithms with adjustable parameters via Victron software tools. -
Day/Night Control & Dimming
Optional timer and light dimming functionality for lighting systems, configurable via software. -
Flexible Monitoring Options
Compatible with Victron GX devices (e.g. Color Control GX) and Bluetooth-enabled devices (via VE.Direct Bluetooth Smart dongle) for real-time data, programming, and history logs.
Specifications:
-
Battery voltage: 12/24V
-
Rated charge current: 15A
-
Nominal PV power, 12V (1a,b): 220W
-
Nominal PV power, 24V (1a,b): 440W
-
Nominal PV power, 36V (1a,b): 4350W
-
Max. PV short circuit current (2): 15A
-
Maximum PV open circuit voltage: 75V
-
Maximum efficiency: 98%
- Self-consumption: 12V: 25 mA 24V: 15 mA
-
Charge voltage 'absorption': 14,4V / 28,8V (adjustable)
-
Charge voltage 'float': 13,8V / 27,6V (adjustable)
-
Charge algorithm: multi-stage adaptive
-
Temperature compensation: -16 mV / °C resp. -32 mV / °C
-
Max. continuous load current: 15A
- Low voltage load disconnect: 13,1V / 26,2V / 52,4V or 14V / 28V / 56V or Battery Life algorithm
- Low voltage load reconnect: 13,1V / 26,2V / 52,4V or 14V / 28V / 56V or Battery Life algorithm
-
Protection : Output short circuit / Over temperature
-
Operating temperature: -30 to +60°C (full rated output up to 40°C)
-
Humidity: 95%, non-condensing
-
Data communication port: VE.Direct
- Dimensions (h x w x d): 100 x 113 x 40 mm
- Weight: 0,5 kg
- Standards: EN/IEC 62109-1, UL 1741, CSA C22.2